Storage and Backups-Netapp
How to create unique aggregate names in a MetroCluster
Description
This Article describes how to create unique aggregate names if accidently duplicate aggregate names got created.
Is Dynamic POD Licensing supported in Fabric MetroCluster or Brocade switches
Applies to
-
MetroCluster
-
ONTAP 9
-
Brocade
Question(s) and Answer(s)
Is Dynamic POD Licensing supported in Fabric MetroCluster for Brocade switches?
-
Dynamic Licensing is supported in MetroCluster starting Ontap 9
-
Dynamic Licensing is not supported in 7mode MetroCluster
Is Dynamic POD Licensing supported in Fabric MetroCluster for Brocade switches?
-
Dynamic Licensing is supported in MetroCluster starting Ontap 9
-
Dynamic Licensing is not supported in 7mode MetroCluster
Should nodes in a MetroCluster DR Group be of the same controller type?
Question(s) and Answer(s)
Should nodes in a MetroCluster DR Group be of the same controller type?
In Data ONTAP, the controller forming a High Availability (HA) pair or a MetroCluster has to be of the same type.
If the system consists of different types, contact your NetApp Sales Representative to resolve the issue.
Should nodes in a MetroCluster DR Group be of the same controller type?
In Data ONTAP, the controller forming a High Availability (HA) pair or a MetroCluster has to be of the same type.
If the system consists of different types, contact your NetApp Sales Representative to resolve the issue.
Controller continually placed offline by alternate
Applies to
Controller: 2660
Firmware Version: 07.75.36.30
Issue
Add your text here.
How to change the NTP server settings in ATTO FibreBridge 6500N
Applies to
-
MetroCluster
-
ATTO 6500N FibreBridge
Description
This article descibes how to change the SNTP (time server) on a ATTO 6500N FibreBridge.
Apply failed for Object: igroup Method: baseline. Reason: Cannot create initiator group X because the initiator is a member of the initiator group Y with conflicting ostype
Issue
The configurations state of a Vserver in a MetroCluster is marked as degraded due to an ostype conflict from an initiator in an igroup belonging to the Vserver.
Cluster : clusterA
Vserver : vserver1
Partner Vserver : vserver1-mc
Configuration State : degraded
Stream Status : operation-failed
Corrective Action : Resynchronize the configuration using "metrocluster vserver resync" command. Contact technical support for assistance if configuration-state does not change to healthy.
...
Failed Reason : Apply failed for Object: igroup Method: baseline. Reason: Cannot create initiator group "igroup_windows" because the initiator "initiator1" is a member of the initiator group "igroup_vmware" with conflicting ostype "vmware".